Quick answer: The AlcoMate AL7000 shows breath alcohol as BAC on its LCD, for example 0.00. Wait for the beep, then read the locked digits. A 0.02 or higher result is a DOT screening positive and is preliminary; confirm with an evidential breath test. American Screening Corp supplies these testers to clinics, courts, and employers.
- Read only the locked BAC after the device beeps and the digits stop changing.
- DOT screening cutoff is 0.02 BAC; confirmation cutoff is 0.04 BAC under 49 CFR Part 40, as of November 2026.
- Every screening positive is preliminary; confirm before any employment, court, or clinical action.
What does an AlcoMate AL7000 result mean?
The AlcoMate AL7000 is a handheld breath alcohol tester used by clinics, treatment centers, probation offices, staffing firms, and employers. It estimates blood alcohol concentration (BAC) from ethanol in a deep-lung breath sample and shows that estimate as a three-digit figure on the LCD.
That figure is percent BAC, reported as 0.00. It is not a urine or oral-fluid cutoff in ng/mL. It is not a medical diagnosis. It is not a final evidential result until your written policy’s confirmation step is complete.
Collectors who call us most often ask whether 0.00 means “no alcohol ever” and whether 0.01 is a fail. 0.00 means the device did not detect alcohol at or above its reporting level at the time of the blow. A 0.01 reading is below the DOT 0.02 screening cutoff in 49 CFR Part 40 (U.S. Department of Transportation, Procedures for Transportation Workplace Drug and Alcohol Testing Programs, as of November 2026).
How do you read AlcoMate AL7000 results step by step?
Follow the manufacturer insert and your program’s collection procedure. The sequence below is the one workplace collectors use when the task is to capture a defensible screening number.
- Fit a new mouthpiece for every donor. Never reuse a mouthpiece.
- Power the unit on. Wait until the display shows it is ready. Do not collect during warmup.
- Enforce a 15-minute deprivation period. The donor must not eat, drink, smoke, vape, or put any substance in the mouth. DOT collections require this wait under 49 CFR Part 40, as of November 2026, because residual mouth alcohol can inflate a reading.
- Instruct a continuous deep-lung blow until the unit signals that the sample is complete.
- Wait for the beep. Digits that are still scrolling are not the result.
- Record the locked BAC, date, time, device identifier, donor ID, and collector name.
- Compare the locked number to your written cutoff. If it meets or exceeds that cutoff, the screen is positive and preliminary. Start confirmation. Do not announce a final result from the screen alone.
Breath alcohol testers are not CLIA-waived laboratory devices. CLIA-waived status applies to certain urine and oral-fluid immunoassay kits, not to a handheld BAC display. Do not claim FDA 510(k) clearance for this unit unless it is on your product record. For DOT work, confirm that the model you use is the screening or evidential device your policy names and, where required, that it appears on the NHTSA Conforming Products List.
What cutoff makes an AL7000 reading positive?
DOT-regulated employers and many courts copy the federal alcohol cutoffs in 49 CFR Part 40. Non-DOT employers may set a different number in policy, but they still need one written cutoff and a confirmation rule before a collector reads the LCD.
| Locked display | Meaning in a DOT-style program | Collector next action |
|---|---|---|
| 0.00 | No alcohol reported at the device’s reporting level | Document and release per written policy |
| 0.01 | Below the 0.02 screening cutoff | Document; do not treat as a DOT screen positive |
| 0.02–0.039 | Screening positive; below the 0.04 confirmation cutoff | Treat as preliminary; run confirmation |
| 0.04 or higher | At or above the DOT confirmation cutoff | Confirm on an evidential breath test; follow Part 40 duty removal if confirmed |
Staffing firms and construction contractors that run DOT and non-DOT pools must label which pool the donor is in before they interpret the number. State court and probation programs follow the statute and standing order that govern that docket, not a collector’s guess.
What does the test detect, and how long does alcohol stay on breath?
The AL7000 detects ethanol in expired breath. It does not detect THC, opioids, amphetamines, cocaine, or other drugs. It does not report urine EtG. Programs that need a drug panel with the breath result should add urine or oral-fluid devices such as drug test cups in 5- to 18-panel configurations.
Breath alcohol can appear within minutes of drinking. It usually falls below common screening cutoffs within about 12 to 24 hours after the last drink, depending on dose, body mass, and time. The CDC describes alcohol use and impairment risk on its alcohol pages (CDC, About Alcohol Use, as of November 2026). Do not quote a single “hours after one drink” figure as if it were universal.
A breath screen is not a urine drug test and is not a saliva test. If your site runs both, keep the alcohol log and the immunoassay log on separate lines so a reviewer can see which cutoff, in which units, applied.
What should a collector do after a positive screen?
Treat every positive screen as preliminary; confirm by GC/MS or LC-MS/MS laboratory testing when your protocol uses blood or urine, or confirm with an evidential breath test when your protocol is DOT breath alcohol. Do not take a final employment, court, or treatment action on the screening LCD alone.
DOT confirmation uses a second breath test on an evidential device after a waiting period, not the screening reading by itself (49 CFR Part 40, Subpart N, as of November 2026). If confirmation is at or above 0.04, a safety-sensitive employee is removed from duty under Part 40. Non-DOT programs follow their handbook.
Do not use a screening BAC to dose medication, to diagnose alcohol use disorder, or to give legal advice. Sister division Reveal Background runs FCRA-compliant employment checks when the same employer also needs a background file; keep that process separate from the breath log.
Collector checklist before you record a result:
- New mouthpiece and ready display
- 15-minute deprivation completed and noted
- Deep-lung sample, not a sip of air
- Locked digits only, written as displayed (for example 0.00 or 0.02)
- Cutoff and program type (DOT or non-DOT) on the form
- Confirmation plan ready for any result at or above cutoff
- Device inside its calibration or sensor-service interval per the insert
- Collector printed name and time
Which reading errors do clinics and courts report most?
Support calls cluster on four mistakes. Reading the display during warmup produces a number that is not a result. Testing right after mouthwash, cough syrup, or a mint can capture mouth alcohol, which is why the 15-minute wait exists. Treating 0.01 as a DOT fail is incorrect; 0.02 is the screen cutoff. Using a screening unit as the sole confirmation device is incorrect for DOT work.
If the donor cannot provide a sample, follow your shy-lung or refusal procedure. Do not keep retesting in a way your policy does not allow. When you need mouthpieces, replacement units, or a paired urine panel, contact American Screening Corp.
Reviewed by the American Screening Corp workplace testing team. Last updated November 2026.
Sources
- Procedures for Transportation Workplace Drug and Alcohol Testing Programs (49 CFR Part 40)
- U.S. DOT Office of Drug and Alcohol Policy and Compliance — 49 CFR Part 40
- CDC — About Alcohol Use
FAQ
What does 0.00 on an AlcoMate AL7000 mean?
0.00 means the unit did not report alcohol at or above its reporting level on that blow. Record the locked digits, time, and device ID. It is a screen, not a medical clearance.
What BAC is a positive workplace alcohol screen?
Under 49 CFR Part 40, as of November 2026, 0.02 BAC is the DOT screening cutoff and 0.04 is the confirmation cutoff. Non-DOT employers use the cutoff written in their policy.
How long after drinking can the AL7000 detect alcohol?
Breath ethanol can appear within minutes and is often undetectable about 12 to 24 hours after the last drink, depending on dose. Do not treat that window as a guarantee for any one donor.
Should I confirm a positive AL7000 reading?
Yes. Every screening positive is preliminary. Confirm with an evidential breath test per 49 CFR Part 40, or by GC/MS or LC-MS/MS laboratory testing when your protocol uses blood or urine.
This page is general information, not medical or legal advice.